Skip to main content
For Laboratory Research Use Only — Not for Human or Veterinary Use
Melanotan II 10mg research peptide vial — Bulk Peptides Company

YOUR LOGO HERE

MELANOTAN II

10mg

For Research Use Only

Lot: —

Bulk Peptides Co.

  • Third-party tested
  • ≥98% HPLC
  • COA per lot
Matrix & Melanocortin Peptides

Melanotan II

For Laboratory Research Use Only — Not for Human or Veterinary Use.

Standard (< 1,000 vials)$180/kit
Volume (1,000+ vials)$130/kit
= 10 vials

Minimum order: 100 vials total. Mix and match across all products.

Specifications
CAS Number121062-08-6
Molecular FormulaC50H69N15O9
Molecular Weight1024.18 g/mol
Purity≥98% (HPLC)
FormLyophilized Powder
Storage-20°C, desiccated, protected from light
ReconstitutionBacteriostatic water
Certificate of Analysis

Lot documentation

Every production lot is independently third-party tested. A batch-specific Certificate of Analysis — documenting HPLC purity, mass spectrometry identity confirmation, and net peptide content — is issued with every shipment. View a sample COA to see the format.

Research context

A cyclic heptapeptide closed by a side-chain lactam bridge, engaging melanocortin receptors without subtype selectivity. Ring closure is the property a lot analysis has to establish.

Structure and molecular target

Melanotan II is a seven-residue analogue of alpha-melanocyte-stimulating hormone, cyclised through an amide bond between the side chain carboxyl of an aspartate and the side chain amine of a lysine. That bridge, formed between side chains rather than through the backbone or through a disulfide, is a lactam, and it is chemically far more stable than the disulfide bridges that close many natural cyclic peptides.

The ring constrains the His-D-Phe-Arg-Trp pharmacophore into a fixed conformation, which is what produces both the potency and the loss of discrimination between receptor subtypes. It is described in the literature as a non-selective melanocortin agonist, with reported activity at MC1R, MC3R, MC4R and MC5R, and that breadth is the substantive difference from Melanotan I rather than a difference of degree.

Findings in the published research literature

Cyclic AMP accumulation across a panel of transfected cell lines expressing individual melanocortin receptor subtypes is the core dataset, since the defining characteristic of this compound is its profile across the family rather than its potency at any one receptor. Radioligand competition assays supply binding affinities alongside the functional numbers.

Melanogenesis endpoints in cultured pigment cells and the classical amphibian melanophore assays provide the MC1R-linked readouts. Rodent work in the literature centres on central melanocortin signalling, where MC3R and MC4R are the expressed subtypes, and this is the portion of the evidence base where a non-selective ligand behaves quite differently from an MC1R-preferring one.

Analytical verification

The critical analytical question for any cyclic peptide is whether the ring actually closed. Lactam formation eliminates one molecule of water, so the cyclised product is exactly 18 daltons lighter than its linear precursor, and mass spectrometry separates the two without ambiguity. A lot report that confirms mass is therefore confirming cyclisation, provided the expected mass quoted is the cyclic one.

Two further impurity classes accompany a cyclisation step. Cyclodimers form when the reaction couples two chains instead of closing one, and appear at approximately double the mass. Incompletely cyclised material can also carry a protecting group, giving another distinct mass. Reversed-phase HPLC resolves these because the compact cyclic conformation is chromatographically distinct from the extended linear form, which typically elutes later.

Handling and storage

SolubilitySoluble in water. The constrained ring keeps the molecule compact and readily solvated.
ReconstitutionDissolves with gentle swirling.
StorageLyophilised powder at -20C, desiccated and protected from light.
StabilityThe lactam bridge is an amide bond and is stable to reducing agents, unlike a disulfide-cyclised peptide, so reducing conditions do not open this ring. Tryptophan photosensitivity remains the practical constraint on solutions.

For Laboratory Research Use Only — Not for Human or Veterinary Use